What was found
LEFT MAIN CABIN FWD FLOOR SUPPORT FR16-FR20 +Y254 HAS CORROSION. BLENDED AREA IAW SRM 51-74-00. CHECKED LIMITS L=2.0" W=1.5" D=0.050". FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14. R & R FLOOR SUPPORT IAW TRM 53-21-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT MAIN CABIN FWD FLOOR SUPPORT FR16-FR20 +Y254 HAS CORROSION. BLENDED AREA IAW SRM 51-74-00. CHECKED LIMITS L=2.0" W=1.5" D=0.050". FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14. R & R FLOOR SUPPORT IAW TRM 53-21-01.