As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LT AFT PASSENGER DOOR CUT OUT, DOOR SILL AFT CORNER FITTING HAS CORROSION. BLENDED AREA IAW SRM 51-74-00. CHECKED LIMITS L=0.484 W=0.502" D=0.125". FOUND TO BE OUT OF LIMITS IAW TRM 53-41-13. R & R AFT CORNER FITTING IAW SRM 51-42-11 AND DWG D53480505. RETAIN FOR RECORDS.