What was found
LIGHTNING DAMAGE TO FUSELAGE SKIN LOCATED RT SIDE BS 780 +60 FIVE INCHES LAP SEAM. REF ERA 514179-14, REV ORIG ITEM 50. REMOVED DAMAGED FASTENER AND C/W EDDY CURRENT INSPECTION. NO DISCREPANCIES. INSTALLED ONE FASTENER. SRM 53-00-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LIGHTNING DAMAGE TO FUSELAGE SKIN LOCATED RT SIDE BS 780 +60 FIVE INCHES LAP SEAM. REF ERA 514179-14, REV ORIG ITEM 50. REMOVED DAMAGED FASTENER AND C/W EDDY CURRENT INSPECTION. NO DISCREPANCIES. INSTALLED ONE FASTENER. SRM 53-00-01.