DURING INSPECTION, FOUND FWD FUSELAGE RT UPPER SPLICE SUPPORT WEB APPROX STR 4R BETWEEN FR 1 & FR 3 HAS SEVERAL TOOL MARKS. REPLACED RT UPPER SPLICE SUPPORT WEB IAW SRM 51-42-11. TOP COATED AREA IAW SRM 51-75-12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND FWD FUSELAGE RT UPPER SPLICE SUPPORT WEB APPROX STR 4R BETWEEN FR 1 & FR 3 HAS SEVERAL TOOL MARKS. REPLACED RT UPPER SPLICE SUPPORT WEB IAW SRM 51-42-11. TOP COATED AREA IAW SRM 51-75-12.