DURING INSPECTION, FOUND LT MLG DOOR FWD HINGE AFT LUG, INBD SIDE IS CHAFED. NO ESTABLISHED LIMITS IAW SRM 53-36-11, PAGE 101. REPLACED FITTING IAW DWG R53370500C & SRM 51-42-11.