What was found
AFT CABIN UTILITY AREA FLOORBEAM BETWEEN FR64-FR66, Y765 UPPER FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00, FOUND OUT OF LIMITS IAW TRM 53-41-15. R & R FLOORBEAM IAW SRM 51-42-1 AND TRM 53-21-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CABIN UTILITY AREA FLOORBEAM BETWEEN FR64-FR66, Y765 UPPER FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00, FOUND OUT OF LIMITS IAW TRM 53-41-15. R & R FLOORBEAM IAW SRM 51-42-1 AND TRM 53-21-01.