What was found
A BONDED REPAIR DOUBLER WAS INSTALLED ON THE HORIZONTAL STABILIZER RT UPPER SKIN PANEL IAW ERA 513426-14AD, SECTION I. REPETITIVE INSPECTIONS AT 1,000 CYCLE INTERVALS AFT SECTION I, REPAIR AND SECTION III ONE TIME INSPECTION AFTER 3,000 CYCLES BUT BEFORE 5,000 CYCLES FROM SECTION I REPAIR INSTALLATION.