What was found
BS 1461, LBL 67 - RBL 51 FLOORBEAM LWR TEE CORRODED CP53-251-01. CORROSION REMOVED IAW SRM 51-10-02 AT LBL8" AND LBL21" BLEND OUT DEPTH 0.027" ORG 0.090" WIDTH 0.95" LENGTH 1.3" OUT OF SRM 53-00-51 ALLOWABLE DAMAGE 1, FIG 101, LIMIT. AT OTHER AREA BLEND OUT DEPTH 0.011" ORG 0.090", WIDTH 0.9", LENGTH 1.3" WITHIN ABOVE LIMITS. REPAIRED IAW ER/A 513070-14, REV ORIG.