What was found
FWD CABIN RT SIDE, BETWEEN FR 20 TO 21, -Y189 FLOOR SUPPORT CORRODED. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14, FIG 105. R & R FLOOR SUPPORT IAW SRM 51-42-11 AND DWG D53111406.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CABIN RT SIDE, BETWEEN FR 20 TO 21, -Y189 FLOOR SUPPORT CORRODED. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14, FIG 105. R & R FLOOR SUPPORT IAW SRM 51-42-11 AND DWG D53111406.