What was found
FWD CABIN RT SIDE BETWEEN FR 12-14 INBD OF -Y189, FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00, FOUND TO BE OUT OF LIMIT IAW SRM 53-11-14. R & R FLOOR SUPPORT IAW SRM 51-42-11 AND DWG D53112622.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CABIN RT SIDE BETWEEN FR 12-14 INBD OF -Y189, FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00, FOUND TO BE OUT OF LIMIT IAW SRM 53-11-14. R & R FLOOR SUPPORT IAW SRM 51-42-11 AND DWG D53112622.