What was found
FWD CABIN RT SIDE, BETWEEN FR16 TO 20 -Y254 FLOOR SUPPORT HAS CORROSION. BLENDED CORRODED IAW SRM 51-74-00. NO ESTABLISHED LIMITS IN SRM 53-11-14, PAGE 102. R & R FLOOR SUPPORT IAW SRM 51-42-11 AND TRM 53-21-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CABIN RT SIDE, BETWEEN FR16 TO 20 -Y254 FLOOR SUPPORT HAS CORROSION. BLENDED CORRODED IAW SRM 51-74-00. NO ESTABLISHED LIMITS IN SRM 53-11-14, PAGE 102. R & R FLOOR SUPPORT IAW SRM 51-42-11 AND TRM 53-21-01.