What was found
CRACK INDICATION FOUND IN FASTENER HOLE LOCATED AT THE WINDSHIELD UPPER AREA OF THE SIDE POST AT FRAME 4, VERTICAL MEMBER LT SIDE. PERFORMED REPAIR AT THE WINDSHIELD UPPER AREA OF THE SIDE POST AT FRAME 4 VERTICAL MEMBER LT SIDE IAW ER/A N 513509-14AD (REV. ORIGINAL) AND PRIN 513509-14AD FROM REV 0 TO REV 3. ACCOMPLISH INITIAL INSPECTION WITHIN 11,000 FLIGHT CYCLES, AFTER SECTION 1 (16-MAY-2013). ACCOMPLISH REPETITIVE INSPECTION AT EVERY 11,000 FLIGHT CYCLES AFTER SECTION 11 IAW ER/A 513509-14AD.