What was found
DURING INSPECTION, FOUND FWD CABIN UTILITY AREA FLOORBEAM BETWEEN FR16 -20, Y254 UPPER FLANGE HAS CORROSION. BLENDED CORROSION IAW SRM 51-74-00 CHECK LIMITS ORIG MAT (0.079"). L=2.5", W=1.47" D=0.43" OUT OF LIMITS IAW SRM 53-11-15, FIG 104. REMOVED BEAM Y254 FROM FR12 TO FR24 IAW SRM 51-42-11. LOCATED & DRILLED NEW BEAM IAW SRM 51-44-11. INSTALLED NEW BEAM IAW TRM 53-21-01.