What was found
DURING INSPECTION, FOUND AFT LT PASSENGER/CREW DOOR SILL BEAM AT FR 68 AFT CORNER FITTING HAS CORROSION. REPLACED FITTING CORNER IAW SRM 51-42-11. DAMAGE DIMENSIONS L=0.400" W=0.080" D=0.025". NO LIMITS FOUND IN SRM 53-41-14, FIG 101.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND AFT LT PASSENGER/CREW DOOR SILL BEAM AT FR 68 AFT CORNER FITTING HAS CORROSION. REPLACED FITTING CORNER IAW SRM 51-42-11. DAMAGE DIMENSIONS L=0.400" W=0.080" D=0.025". NO LIMITS FOUND IN SRM 53-41-14, FIG 101.