What was found
STRINGER 16L DAMAGED AT BS 620. DAMAGED SECTION OF STRINGER CUT OUT, PERFORMED HFEC OF ALL INITIAL FASTNER HOLES IAW SRM 53-00-03. REPAIR 1, REF PRI 515520-14, REV 0, NO ITEMS NOTED, FABRICATED AND INSTALLED REPAIR SPLICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER 16L DAMAGED AT BS 620. DAMAGED SECTION OF STRINGER CUT OUT, PERFORMED HFEC OF ALL INITIAL FASTNER HOLES IAW SRM 53-00-03. REPAIR 1, REF PRI 515520-14, REV 0, NO ITEMS NOTED, FABRICATED AND INSTALLED REPAIR SPLICE.