What was found
CORROSION ON FLOORBEAM ANGLE BS 1309 X=-20. CORROSION WAS REMOVED IAW SRM 51-10-3 OAR 26 MEASURED AND FOUND OUT OF LIMITS IAW SRM 53-01, FIG 1. REPAIRED IAW ER/A 514805-14 REV ORIGINAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOORBEAM ANGLE BS 1309 X=-20. CORROSION WAS REMOVED IAW SRM 51-10-3 OAR 26 MEASURED AND FOUND OUT OF LIMITS IAW SRM 53-01, FIG 1. REPAIRED IAW ER/A 514805-14 REV ORIGINAL.