What was found
DURING INSPECTION, FOUND AFT CABIN UTILITY AREA FLOOR SUPPORT BETWEEN FR 68-69, Y-1292 UPPER FLANGES & HARD POINT HOLES HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00 DIMENSION L=2.0" W=1.25" D=0.065". FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15; REPLACED FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.