What was found
DURING INSPECTION, FOUND AFT CABIN UTILITY AREA FLOOR SUPPORT BETWEEN FR 65-66, Y1292. UPPER SURFACE & HARD POINT HOLES HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00 BLEND SIZE: L=1.6" W=1.3" D=.030" FOUND TO BE OUT OF LIMIT IAW TRM 53-41-15, ORIGINAL MATERIAL .087". R & R WITH NEW FLOOR SUPPORT BETWEEN FR64-FR66 Y1292 IAW TRM 53-21-01 & SRM 51-42-11.