What was found
DURING INSPECTION FOUND AFT CARGO COMPARTMENT, RT FLOOR SUPPORT CHANNEL HAS CORROSION AROUND 2 FASTENER HOLES STA 727I+5, RBL 3. REMOVED CORROSION DAMAGE, INSTALLED SPLICE. REPAIRED FLOOR ANGLE SUPPORT STA 727I+5, RBL 3 IAW ERA 492969-14MA, REV ORIGINAL AND SRM 53-00-53 RESTORED PRESERVATION TO SPLICE REPAIR.