What was found
DURING INSPECTION, FOUND MID CABIN FLOOR SUPPORT BETWEEN FR 32 AND FR 33 AT -Y245 UPPER FLANGE DAMAGED. BLENDED AREA IAW SRM 51-73-00, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG 204, CUTOUT DAMAGED AREA. FABRICATED REPAIR PARTS ONE ANGLE AND ONE FILLER, LOCATED AND DRILLED REPAIR PARTS IAW 51-44-11, INSTALLED REPAIR PARTS IAW SRM 53-00-14, FIG 204.