What was found
DURING INSPECTION, FOUND DENT ON EXTERNAL FUSELAGE SKIN LOCATED FR 24+7" AND BETWEEN STR 41L AND STR 42L. PERFORMED PERMANENT REPAIR ON EXTERNAL FUSELAGE SKIN BETWEEN FR 24 AND FR 25 AND BETWEEN STR 41L AND STR 43L IAW SRM 53-21-11, PARA 5K, FIG 214, MUST BE INSPECTED FIRST INSP AFTER REPAIR EMBODIMENT AT 60000 FC/FH NOT RELEVANT IAW SRI 53-21-11-2-003-00, PARA 3.C, TABLE 204.