What was found
DURING HFEC OPEN HOLE INSPECTION AT BS 1809.5, LT BULKHEAD ON AREA WITH RUB STRIPS INSTALLED, CRACK INDICATION FOUND ON LWR FWD HOLE AT SECOND LAYER FROM INBD APPROX THREE O'CLOCK POSITION IAW CARD 5310-01376-1603, STEP 3, BS 1809.5 BULKHEAD OUTER CHORD, LT PERMANENT REPAIR.