What was found
DURING INSPECTION, FOUND PASSENGER COMPARTMENT, BS 986 FLOORBEAM, RBL 43 HAS UPPER SURFACE CORROSION AROUND FASTENER HOLE. MX REMOVED CORROSION AT BS 986, RBL43, REPAIRED FLOORBEAM IAW ER/A 464736-14MA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND PASSENGER COMPARTMENT, BS 986 FLOORBEAM, RBL 43 HAS UPPER SURFACE CORROSION AROUND FASTENER HOLE. MX REMOVED CORROSION AT BS 986, RBL43, REPAIRED FLOORBEAM IAW ER/A 464736-14MA.