What was found
DURING INSPECTION, FOUND AFT CARGO BAY FR58 - 59 S42L CORRODED. CLEANED AREA IAW AMM 12-21-12. NO LIMITS ON CORROSION ESTABLISHED IAW SRM 53-41-13, FIG 101. REMOVED DAMAGED STRINGER IAW SRM 53-00-13, FIG 201, SHT. 2. REPAIRED STRINGER IAW SRM 53-00-13, FIG 201. PERMANENT IAW PS900-5-1 NR 4. FIRST INSPECTION AFTER REPAIR REQUIRED AT 60000FC IAW SRI 53-00-13 PAGE 210.