What was found
FOUND CORROSION HOLE 4 INCHES FWD OF BS 1197+154 AND 3 INCHES ABOVE STR 31R. REMOVED CORROSION LEAVING ABOUT 2.5 INCHES LONG BY ABOUT 1 INCH HIGH HOLE. PERFORMED HFEC IAW NDTSPM 06-01-10 PART 6 CORROSION CONTAINED, NO CRACKS NOTED FOR CUTOUT. FABRICATED DOUBLER IAW SRM 53-00-01, REPAIR 14. FINISHED SIZING HOLES. CONTOURED DOUBLER INSTALLED WET, TREATED AND PRIMED, MARKED REPAIR AS SRM 53-00-01, REPAIR 14, DATED AND PAINTED. RE-INSTALLED ACCESS IN AFT CARGO.