What was found
DURING INSPECTION, FOUND FWD CARGO COMPT BILGE AREA AT FR 28 STGR 41R -42R CLIP HAS CORROSION. REMOVED SHEAR CLIP IAW SRM 51-42-11. NO ALLOWABLE DAMAGE LIMITS FOUND IN SRM. FABRICATED, LOCATED & DRILLED, TREATED AND PRIMED, APPLIED TOPCOAT, AND INSTALLED NEW SHEAR CLIP IAW SRM 51-44-11, 51-21-11, 51-75-12, AND 51-42-11.