What was found
CABIN FWD WET AREA FLOOR STRUCTURE RT SIDE BS 200 -237+8" RBL 45, SEAT TRACK CORRODED. TASK 53-211-01. REMOVED CORROSION. FOUND TO BE OUT OF LIMITS. R & R SEAT TRACK BS 200-245, RBL45 IAW SRM 53-40-01, PG 30, FIG 6.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FWD WET AREA FLOOR STRUCTURE RT SIDE BS 200 -237+8" RBL 45, SEAT TRACK CORRODED. TASK 53-211-01. REMOVED CORROSION. FOUND TO BE OUT OF LIMITS. R & R SEAT TRACK BS 200-245, RBL45 IAW SRM 53-40-01, PG 30, FIG 6.