What was found
PASSENGER CABIN FORWARD WET AREA FLOORBEAM RT SIDE BS 180, RBL 9 -45, FLOORBEAM CORRODED. TASK 53-211-01. REMOVED CORROSION. FOUND TO BE OUT OF LIMITS. REPLACED FLOORBEAM RT SIDE BS 180, RBL 9 -45 IAW SRM 51-30-02 AND 53-00-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PASSENGER CABIN FORWARD WET AREA FLOORBEAM RT SIDE BS 180, RBL 9 -45, FLOORBEAM CORRODED. TASK 53-211-01. REMOVED CORROSION. FOUND TO BE OUT OF LIMITS. REPLACED FLOORBEAM RT SIDE BS 180, RBL 9 -45 IAW SRM 51-30-02 AND 53-00-01.