What was found
DURING INSPECTION, FOUND AFT CARGO BETWEEN FR 58-59, STR 44, FLOOR SUPPORT HAS SURFACE CORROSION. BLENDED CORROSION. BLENDED CORROSION IAW SRM 51-74-00. NO ESTABLISHED LIMITS IAW SRM 53-41-14, REPLACED FLOOR SUPPORT IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND AFT CARGO BETWEEN FR 58-59, STR 44, FLOOR SUPPORT HAS SURFACE CORROSION. BLENDED CORROSION. BLENDED CORROSION IAW SRM 51-74-00. NO ESTABLISHED LIMITS IAW SRM 53-41-14, REPLACED FLOOR SUPPORT IAW SRM 51-42-11.