What was found
DURING SCHEDULED INSPECTION, EXFOLIATION CORROSION WAS FOUND AT LONGERON L22 AT BS 1287. INSTALLED LONGERON SPLICES IAW SRM 53-02, FIG 18.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED INSPECTION, EXFOLIATION CORROSION WAS FOUND AT LONGERON L22 AT BS 1287. INSTALLED LONGERON SPLICES IAW SRM 53-02, FIG 18.