AFT UTILITY AREA BETWEEN FR 67 AND 68 FLOOR SUPPORT -Y129 2 HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. R & R FLOOR SUPPORT IAW SRM 51-42-11 AND TRM 53-21-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT UTILITY AREA BETWEEN FR 67 AND 68 FLOOR SUPPORT -Y129 2 HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. R & R FLOOR SUPPORT IAW SRM 51-42-11 AND TRM 53-21-01.