What was found
PASSENGER CABIN FWD WET AREA FLOOR STRUCTURE RT SIDE BS 160 -200 RBL 54 THRESHOLD STRAP CORRODED. TASK NR 53-211-01. R & R OUT OF LIMITS STRAP AND FILLER AT R1 DOOR FLOOR IAW SRM 53-00-01 AND DWG 9957828.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PASSENGER CABIN FWD WET AREA FLOOR STRUCTURE RT SIDE BS 160 -200 RBL 54 THRESHOLD STRAP CORRODED. TASK NR 53-211-01. R & R OUT OF LIMITS STRAP AND FILLER AT R1 DOOR FLOOR IAW SRM 53-00-01 AND DWG 9957828.