What was found
DENT IN FWD FUSELAGE AT APPROX BS 3850 FR2, STRINGER 22 . REMOVED DAMAGE IN SKIN. FABRICATED REPAIR PART IAW SRM 53-11-11, FIG 210. REPAIRED IAW SRM 53-11-11, PG 291.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DENT IN FWD FUSELAGE AT APPROX BS 3850 FR2, STRINGER 22 . REMOVED DAMAGE IN SKIN. FABRICATED REPAIR PART IAW SRM 53-11-11, FIG 210. REPAIRED IAW SRM 53-11-11, PG 291.