What was found
LT AFT DOOR SILL, AFT SHAPE SILL AROUND FASTENER HOLES CORRODED. REMOVED CORROSION IAW SRM 51-74-00 NO ESTABLISHED LIMITS ON SRM. LOCATED AND DRILLED NEW FITTING CORNER IAW SRM 51-44-11. INSTALL NEW FITTING.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT AFT DOOR SILL, AFT SHAPE SILL AROUND FASTENER HOLES CORRODED. REMOVED CORROSION IAW SRM 51-74-00 NO ESTABLISHED LIMITS ON SRM. LOCATED AND DRILLED NEW FITTING CORNER IAW SRM 51-44-11. INSTALL NEW FITTING.