What was found
AFT CABIN FLOOR SUPPORT FR 66 TO 68 AROUND FASTENER HOLES CORRODED. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. R & R FLOOR SUPPORT IAW SRM 51-42-11 & DWG D5347200.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CABIN FLOOR SUPPORT FR 66 TO 68 AROUND FASTENER HOLES CORRODED. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. R & R FLOOR SUPPORT IAW SRM 51-42-11 & DWG D5347200.