What was found
DENT IN FUSELAGE SKIN ON FR 13 S22-23L. DENT FOUND TO BE OUT OF NEARNESS B=0.200" LESS THAN 0.590 IAW SRM 53-11-11, FIG 105. CUT OUT DAMAGED AREA IAW SRM 53-00-11. HFEC IAW NTM 51-10-08, PT6, NO DEFECTS NOTED. FABRICATED AND INSTALLED FILLER, DOUBLER IAW SRM 53-00-11, FIG 232.