What was found
CORROSION ON FLOOR SUPPORT LOCATED FWD PAX CABIN BETWEEN FR 20 AND 24 , Y-254. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53111462.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR SUPPORT LOCATED FWD PAX CABIN BETWEEN FR 20 AND 24 , Y-254. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53111462.