FWD UTILITY AREA FLOOR SUPPORT BETWEEN FR16-FR18, Y1292 UPPER SURFACE FLANGE HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00 AND FOUND TO BE OUT OF LIMITS IAW SRM 53-11-15. R & R FLOOR SUPPORT IAW TRM 53-21-01.