What was found
AFT LAVATORY WET AREA, BS 1364, LBL 14- RBL 11, FLOORBEAM CORRODED ON UPPER SURFACE. REMOVED CORROSION. FOUND TO BE OUT OF LIMITS. INSTALLED NEW FLOORBEAM IAW DWG 5930961, REV BL AND SRM 51-30-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT LAVATORY WET AREA, BS 1364, LBL 14- RBL 11, FLOORBEAM CORRODED ON UPPER SURFACE. REMOVED CORROSION. FOUND TO BE OUT OF LIMITS. INSTALLED NEW FLOORBEAM IAW DWG 5930961, REV BL AND SRM 51-30-00.