What was found
DURING INSPECTION, FOUND CORROSION ON WEB LOCATED AT LEVEL OF FR 16, RT FLOOR STRUCTURE STRG 23R. REPLACED WEB AND FASTENER IAW SRM 51-72-11 AND DWG D53112780.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON WEB LOCATED AT LEVEL OF FR 16, RT FLOOR STRUCTURE STRG 23R. REPLACED WEB AND FASTENER IAW SRM 51-72-11 AND DWG D53112780.