What was found
AFT CARGO DOOR CUTOUT LOWER SILL UPPER WEB UPPER SURFACE CORRODED BS 1380-1440. FOUND TO BE OUT OF LIMITS IAW SRM-53-00-53 ALLOWABLE DAMAGE 1, PG-105, DETAIL V. LOCATED AND DRILLED NEW TRANSITION PANEL IAW-SRM-51-40-05, PG-2. INSTALLED PANEL IAW SRM-51-40-02, PG-7,21 AND PS 900-2, NR 05, UPPER WEB IS TRANSITION PANEL.