What was found
FLOORBEAM BS 480, LBL60, WL 199.8 CORRODED. SECTION CUT OUT AND FABRICATED REPAIR PARTS IAW, SRM53-10-51, REPAIR 3 . HFEC INSPECTED AND NO CRACK FOUND.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM BS 480, LBL60, WL 199.8 CORRODED. SECTION CUT OUT AND FABRICATED REPAIR PARTS IAW, SRM53-10-51, REPAIR 3 . HFEC INSPECTED AND NO CRACK FOUND.