What was found
DURING INSPECTION, FOUND CORROSION ON THRESHOLD SHEET LOCATED BETWEEN FR 24A TO FR 28 FWD CARGO COMP SSI 532180. MEASURES ARE: L=0.890", W=0.425", D=0.001". REPLACED THRESHOLD SHEET LOCATED BETWEEN FR 24A TO FR 28 FWD CARGO COMPARTMENT IAW SRM 51-72-11 AND DWG D53231264.