What was found
LEFT AFT DOOR FRAME AT FRAME 68 MID ROLLER STOP FITTING CHAFED. BLENDED AREA IAW SRM 51-73-00. NO ESTABLISHED LIMIT ON SRM. R & R STOP FITTING IAW SRM 51-42-11 & DWG D53480082.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT AFT DOOR FRAME AT FRAME 68 MID ROLLER STOP FITTING CHAFED. BLENDED AREA IAW SRM 51-73-00. NO ESTABLISHED LIMIT ON SRM. R & R STOP FITTING IAW SRM 51-42-11 & DWG D53480082.