What was found
CORROSION FOUND ON FLOOR SUPPORT -Y1225 LOCATED BETWEEN FRAMES 66+4" - 67+15" IN PAX CABIN. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472000.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON FLOOR SUPPORT -Y1225 LOCATED BETWEEN FRAMES 66+4" - 67+15" IN PAX CABIN. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472000.