What was found
CORROSION ON FLOOR SUPPORT AT +Y1225 BETWEEN FRAMES 66+4" AND 67+15". REPLACED FLOOR SUPPORT IAW SRM A320 51-72-11 AND DWG D53472000 AND REPLACED SPLICE IAW SRM 51-72-11, LOCATION FR 66+4" UPPER INBD POSITION IAW DWG D53472230.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR SUPPORT AT +Y1225 BETWEEN FRAMES 66+4" AND 67+15". REPLACED FLOOR SUPPORT IAW SRM A320 51-72-11 AND DWG D53472000 AND REPLACED SPLICE IAW SRM 51-72-11, LOCATION FR 66+4" UPPER INBD POSITION IAW DWG D53472230.