What was found
FLOORBOARD 127CF HAS FOUR DAMAGED SCREW MOUNT HOLES. FOUND OUT OF LIMIT IAW SRM 53-12-00, DIAGRAM 101. FABRICATED NEW FLOORBOARD IAW SRM 53-12-00, FIG 206.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBOARD 127CF HAS FOUR DAMAGED SCREW MOUNT HOLES. FOUND OUT OF LIMIT IAW SRM 53-12-00, DIAGRAM 101. FABRICATED NEW FLOORBOARD IAW SRM 53-12-00, FIG 206.