What was found
SKIN AT FRAMES 70 - 71, STR 16 - 17 RIGHT DENTED. BLENDED GOUGE IAW SRM 51-73-00. NO ESTABLISHED LIMIT IAW SRM 53-51-11, TABLE 101. CUT OUT DAMAGE. FABRICATED REPAIR DOUBLER IAW SRM 53-00-11, FIG 230 AND INSTALLED IAW SRM 51-42-11 AND SRM 53-00-11, FIG 230.