What was found
FORWARD CABIN FLOOR SUPPORT Y-189 BETWEEN FRAMES 20-24 UPPER FLANGE HAS CORROSION. R & R FWD CABIN FLOOR SUPPORT IAW TRM 53-21-01 & SRM 51-42-11. BLENDED AREA IAW SRM 51-74-10. FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14, FIG 107.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD CABIN FLOOR SUPPORT Y-189 BETWEEN FRAMES 20-24 UPPER FLANGE HAS CORROSION. R & R FWD CABIN FLOOR SUPPORT IAW TRM 53-21-01 & SRM 51-42-11. BLENDED AREA IAW SRM 51-74-10. FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14, FIG 107.