What was found
CORROSION ON STRINGER SPLICE 41R LOCATED AT FRAME 30+15" FWD CARGO BAY. REPLACED STRINGER SPLICE IAW SRM 51-72-11 AND DWG D53231586.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON STRINGER SPLICE 41R LOCATED AT FRAME 30+15" FWD CARGO BAY. REPLACED STRINGER SPLICE IAW SRM 51-72-11 AND DWG D53231586.